What are winder stairs?
Winders are tapered treads that turn a stair through a corner while it keeps climbing — the stair's answer to a corner landing. Because each winder is also a step up, a winder turn takes less floor than a landing: about one tread less along each wall for a 36 in stair. The price is a tread that is deep at the wall and narrow at the inside, so the codes set minimum depths at two places: on the walkline, where people actually walk, and at the narrow end.
IRC winder requirements
| Rule | US — IRC (R311.7.5.2.1) | UK — Approved Document K |
|---|---|---|
| Where depth is measured | Walkline, 12 in from the inside edge of the clear width | Centre line of the stair (stairs under 1 m wide) |
| Depth on that line | At least 10 in | At least the going of the straight treads |
| Narrow end | At least 6 in at any point within the clear width | At least 50 mm |
| Uniformity | Walkline depths within 3/8 in of each other | Consistent goings through the turn |
| Stride and pitch | Riser up to 7¾ in | 2R + G 550–700 mm, pitch up to 42° (private stair) |
Canada and Australia have their own winder rules and are shown as geometry only; the auto radius for them, and for None, uses the IRC-style 10 in walkline and 6 in narrow end as a sensible starting point.
How the winder calculator works
The nosing lines of the winders radiate from one turn centre. The inside edge of the clear width is an arc of radius ri about that centre, and the outside walls form a square corner box. With a turn of 90° or 180°, k winders per 90°, clear width W and riser R:
winders nw = k × turn ÷ 90 · winder angle θ = turn ÷ nw
walkline radius rw = ri + 12 in (UK: ri + W ÷ 2)
walkline depth = 2 × rw × sin(θ ÷ 2) · narrow end = 2 × ri × sin(θ ÷ 2)
minimum ri (IRC) = max(10 ÷ (2 sin(θ ÷ 2)) − 12, 6 ÷ (2 sin(θ ÷ 2))), rounded up to 1/16 in
minimum ri (UK) = max(G ÷ (2 sin(θ ÷ 2)) − W ÷ 2, 50 ÷ (2 sin(θ ÷ 2))), rounded up to 1 mm
corner box B = ri + W (180°: 2B wide × B deep) · 2R + T = 2R + walkline depth · pitch = atan(R ÷ walkline depth)
Each depth is the straight-line chord between two nosing lines, which is how a tape measures it. The outer-end width of each winder is the distance between the points where its two nosing lines meet the walls of the box. Leave Inside radius blank and the calculator uses the minimum that passes.
Worked examples
An IRC quarter turn with 3 winders
- Inputs90° turn · 3 winders · 36 in clear width · inside radius blank (auto) · 7¼ in riser · 10½ in straight treads · IRC.
- Angle90 ÷ 3 = 30° per winder; 2 sin 15° = 0.5176.
- Minimum radiusmax(10 ÷ 0.5176 − 12, 6 ÷ 0.5176) = max(7.32, 11.59) = 11.59 → 11-5/8 in. The narrow end decides it.
- DepthsWalkline radius 23.62 in → walkline depth 12.23 in (12-1/4"); narrow end 6.02 in (6"). Both pass.
- FramingCorner box 47.62 in square; the winders are 27.50, 28.47 and 27.50 in wide at the walls.
- Feel2R + T = 26.73 in on the walkline; pitch 30.7°.
The classic failure: a tight corner
Wind the same three winders round a 2 in newel and the walkline is only 7.25 in deep and the narrow end 1.04 in — both fail. The fix is an inside radius of at least 11-5/8 in, two winders per 90° (which pass from 7-7/8 in), or a landing.
How many winders in a turn?
| Winders per 90° | Angle | IRC: min radius · walkline · box | UK: min radius · centre-line going · 2R + G |
|---|---|---|---|
| 2 | 45° | 7-7/8" · 15-3/16" · 43-7/8" | 66 mm · 380 mm · 780 mm (over 700 — fails) |
| 3 | 30° | 11-5/8" · 12-1/4" · 47-5/8" | 97 mm · 273 mm · 673 mm |
| 4 | 22.5° | 15-7/16" · 10-11/16" · 51-7/16" | 186 mm · 240 mm · 640 mm |
Fewer winders pass at a smaller radius but give long, flat treads; more winders need a larger radius and a bigger box. Three is the usual balance. The table under your result shows these options for your own width and rule set.
Checking existing winders
Choose Check existing winders, pick how many there are and enter, for each, the depth at the walkline (nosing to nosing, 12 in from the inside edge) and the depth at the narrowest point. The calculator checks every winder against the minimums and works out the uniformity range — the deepest walkline depth minus the shallowest — which the IRC limits to 3/8 in.
Site-built winders often fail on uniformity even when each tread looks fine: walkline depths of 10¾, 10 and 9¾ in vary by a full inch, and the shallowest is under 10 in. Well-built winders vary by a quarter inch or less.
UK kite winders
In the UK a quarter turn of three winders is often called a kite winder, after the shape of the middle tread. For a stair under 1 m wide, Approved Document K measures the going on the centre line and needs it to be at least the straight going, with at least 50 mm at the narrow end. In an 860 mm stair with 240 mm goings and a 100 mm inside radius, three winders give 274 mm on the centre line and 52 mm at the narrow end, and 2R + G of 674 mm — a pass.
Winders vs a landing
A landing is the safer, easier turn: a flat rest, room to pivot with furniture and no tapered treads. Winders save about a tread of length on each wall, which is often the reason they are chosen. If you use winders, keep them identical, keep the walkline depth comfortably over the minimum, put the handrail on the outside and light the turn. Compare the two with the L-shaped stair calculator or the staircase footprint calculator.
What this calculator does not cover
- The flights before and after the turn: use the L-shaped or U-shaped stair calculator.
- Unequal winders or winders that do not radiate from one centre — check them tread by tread with Check existing winders.
- Spiral and curved stairs, which turn all the way: use the spiral and curved stair calculators.
- Handrails, carpet and a full code report for the whole stair.
Winder stair FAQs
What are winder stairs?
Winders are wedge-shaped treads that turn a stair through a corner instead of a flat landing — usually three for a 90° turn. They save space because they keep climbing while they turn, but they are narrow at the inside and need care to be safe.
What are the IRC requirements for winder treads?
Under IRC R311.7.5.2.1, each winder must be at least 10 in deep at the walkline and at least 6 in deep at any point within the clear width, and the walkline depths of the winders must be within 3/8 in of each other. The walkline is 12 in from the inside edge of the clear width.
Where is the walkline on a winder stair?
Under the IRC it is a line 12 in from the inside edge of the clear stair width, following the curve of the turn. Winder depth is measured on that line between the nosings. In the UK, for stairs narrower than 1 m, the going is measured on the centre line of the stair.
How many winders are in a quarter turn?
Three is the usual number, each turning 30°. Two winders (45° each) pass the IRC with a smaller inside radius — about 7⅞ in against 11⅝ in — but give deep, flat treads; four winders (22½° each) need an inside radius of about 15½ in.
How do you lay out winder treads?
Mark the turn centre at the inside corner, then draw the inside edge as an arc at the inside radius and the walkline 12 in further out. Divide the turn into equal angles and draw a nosing line from the centre for each winder out to the walls. Check each tread at the walkline and at the narrow end, then frame the corner box to the size the calculator gives.
Can winders come to a point at the inside corner?
Not under the IRC. A tread that narrows to a point has no depth at the narrow end, and the code needs at least 6 in at every point within the clear width. Pie-shaped winders round a small newel are the classic non-compliant winder; move the inside edge away from the turn centre — an offset newel or a curved inside stringer — until the narrow end reaches 6 in.
Are winder stairs safe?
They can be, but turns are where most stair falls happen. Keep every winder the same, keep the walkline depth at least as deep as code requires, fit the handrail on the outside where people naturally walk, and light the turn well. A landing is safer if you have the space.
What are the UK rules for kite winders?
Under Approved Document K, the going of a tapered tread is measured on the centre line for stairs under 1 m wide and must be at least the going of the straight treads; every tread needs at least 50 mm at the narrow end; and 2R + G and the pitch must stay within the same limits as the straight flight (550–700 mm and 42° for a private stair).
Can a U-shaped stair use winders?
Yes — a 180° turn usually uses six winders, three for each 90°, with the same geometry per winder as a quarter turn. It shortens the stairwell compared with a half landing; the corner box is twice as wide as it is deep.
Sources
- International Residential Code 2021, Section R311.7.5.2.1 — Winder treads (opens in a new tab)International Code Council. 10 in minimum depth at the walkline, 6 in minimum at any point within the clear width, 3/8 in maximum difference between winders (R311.7.5.2.1); walkline 12 in from the inside edge of the clear width (R311.7.4); 7¾ in maximum riser.
- Approved Document K: Protection from falling, collision and impact (opens in a new tab)UK Government (statutory guidance for England). Tapered treads: going measured on the centre line for stairs under 1 m wide, not less than the straight going, at least 50 mm at the narrow end; 2R + G 550–700 mm; 42° maximum pitch for a private stair.
- Winder geometryDerived from geometry: the depth of a winder at any radius is the chord 2r sin(θ ÷ 2) between consecutive nosing lines, and the outer-end widths are the distances between the points where the nosing lines meet the corner box.
Code text is the final word. Editions and local amendments differ — check the edition your building department enforces.
Related calculators
- L-shaped stair calculatorUse a corner landing instead
- U-shaped stair calculatorLay out a half-turn stair
- Staircase footprint calculatorWinders vs landing: the space saved
- Spiral staircase calculatorTurn all the way round
- Curved stair calculatorA whole stair on a curve
- Stair calculatorRisers and treads for the flights
Other stair calculator categories