Stair Stringer Calculator

Enter your total rise — or a riser and tread you already have — and get everything needed to mark, cut and buy stair stringers: framing-square settings, the throat left below each notch, the board length to buy, the first-riser drop, the number of stringers and the saw angles.

By the Stair-Math TeamUpdated How we check this calculator

What are you laying out?

Your stair and board

in

Finished floor to finished floor. Not sure? Work out your total rise.

in

Adjusted so every riser is equal and within code.

in

Riser face to riser face — the framing-square blade setting.

in

Hardwood 1-1/16 in · 5/4 decking 1 in · 2x lumber 1½ in.

Actual depth, not nominal. Most cut stringers are 2x12.

Quick picks — tread material:

Top step
Units

Your stringer layout

— risers
Your cut stringer drawn to scale on its board, with the throat, cuts and length to buy
Drag the yellow handle to change the tread run — the throat and length follow. Next mark steps along the notches.

Stringer check

    Solved with your numbers

      Assumptions: all risers are equal; lumber is standard dressed size (a 2x12 is 11¼ in deep); throat is measured square from the inside corner of a notch to the bottom edge of the board; housed stringers are not notched; the length needed includes one extra step diagonal as a buying allowance, not a cut length. All risers must match within 3/8 in once treads and flooring are installed.

      Riser and tread limits from the IRC (R311.7) and the codes listed under Sources; throat, spacing and span rules from prescriptive deck construction rules. Tested against 4 worked cases, including a failing 2x10 and a metric stair. See the method · Sources

      How to mark a stair stringer with a framing square

      A stringer is laid out with two numbers: the riser height on the tongue of the framing square and the tread run on the blade. Set stair gauges (or clamp a straight stick) at those two marks so every notch comes out the same.

      1. Set the squareClamp a gauge on the outside of the tongue at the riser height (for example 7-3/16") and on the blade at the tread run (10-1/2"). Use the outside edge, the same edge for both.
      2. Mark the first notchWith both gauges touching the top edge of the board, trace along the tongue (riser line) and the blade (tread line). Start far enough from the end to leave room for the bottom level cut.
      3. Step along the boardSlide the square so the tongue lines up with the end of the last tread line and trace again. Repeat until you have one notch per tread — one fewer than the risers on a standard stair.
      4. Mark the cutsExtend the last riser line down for the plumb cut against the header, and draw the level cut at the foot. Then measure the tread thickness up from the bottom cut and remove it — the first-riser drop.
      5. Cut and copyCut the notches with a circular saw, stop short of the inside corners and finish with a handsaw so you do not over-cut into the throat. Test the first stringer in place, then trace it onto the others.

      The step-height table under the result lists the finished height of every tread above the lower floor. Mark those heights on a straight stick held against the wall — a story pole — to check the stringer before you cut the rest.

      How the stair stringer calculator works

      In Layout from total rise, the calculator first splits the rise into equal risers exactly like the stair calculator, keeping the riser within the code you choose. In Known riser & tread, you enter the riser, tread and number of risers from a plan or an existing stair, and the total rise is derived from them. Then it works out the cut layout:

      step diagonal h = √(R² + T²)

      notch depth = R × T ÷ h — the depth each notch cuts square into the board

      throat = board depth − R × T ÷ h

      length needed = (notches + 1) × h · stock = the shortest of 8, 10, 12 … 20 ft that covers it

      first-riser drop = tread thickness − flooring still to be laid at the bottom

      stringers = max(2, ceil(width ÷ spacing) + 1)

      level cut = atan(R ÷ T) · plumb cut = 90° − level cut

      Where the throat formula comes from

      Each notch is a right triangle with the riser and the tread as its two short sides and the step diagonal as its long side, which lies along the top edge of the board. The inside corner of the notch sits R × T ÷ h below that edge — the height of the triangle measured square to its long side. Whatever board depth is left below the corner is the throat, and it carries the whole load of the stair.

      A cut stringer with its notches, the notch depth, the throat below the inside corner and the board depth Throat Notch depth Riser (tongue)Tread (blade) BOARD DEPTH
      The board’s top edge runs along the step diagonals. The throat is the wood left square to the bottom edge below each inside corner.

      Units

      Work in inches, feet-inches, millimetres, centimetres or metres, or type a unit into any field — 7 3/16, 1-1/16, 290mm. Riser and tread settings are shown to 3 decimals and to the nearest 1/16 in, the resolution of a framing square. Conversions use 1 in = 25.4 mm exactly.

      Worked example: stringers for a 9 ft interior stair

      A 108 in finished rise, 7¼ in target risers, 10½ in treads of 1 in thick oak, no flooring to add at the bottom, 2x12 cut stringers, a 36 in wide stair at 18 in on center, IRC, standard top step.

      1. Risersn = round(108 ÷ 7.25) = 15; R = 108 ÷ 15 = 7.200 in — set the tongue at 7-3/16".
      2. Notches15 − 1 = 14 notches; set the blade at 10-1/2".
      3. Step diagonalh = √(7.2² + 10.5²) = 12.73 in.
      4. Throat11.25 − 7.2 × 10.5 ÷ 12.73 = 11.25 − 5.94 = 5.31 in (5-5/16") — passes the 5 in minimum.
      5. Length to buy(14 + 1) × 12.73 = 190.97 in (15.91 ft) → buy 16 ft boards.
      6. Drop, count and cutsDrop = 1 − 0 = 1 in. Stringers = ceil(36 ÷ 18) + 1 = 3. Level cut 34.4°, plumb cut 55.6°.
      7. ResultThree 16 ft 2x12s, each with 14 notches at 7-3/16 × 10-1/2, 5-5/16" of throat, 1" off the bottom; step heights 7.20, 14.40, 21.60 … 100.80 in.

      What size lumber for stair stringers?

      The throat decides the board. A notch for ordinary residential steps cuts about 6 in square into the board, so the board depth minus 6 in is roughly what is left to carry the stair. Prescriptive deck rules ask for at least 5 in.

      Throat left by common steps (cut stringers, actual board depths)
      Riser × treadNotch depth2x10 (9¼ in)2x12 (11¼ in)LVL 11-7/8 in
      7¾ × 10 in (IRC steepest)6.13 in3.12 in — fails5.12 in — passes5.75 in — passes
      7½ × 10½ in6.10 in3.15 in — fails5.15 in — passes5.77 in — passes
      7.20 × 10½ in5.94 in3.31 in — fails5.31 in — passes5.94 in — passes
      7 × 11¼ in (deck, two 2x6)5.94 in3.31 in — fails5.31 in — passes5.93 in — passes
      6-11/16 × 11¼ in5.74 in3.51 in — under 5 in5.51 in — passes6.14 in — passes
      6 × 12 in (gentle)5.37 in3.88 in — under 5 in5.88 in — passes6.51 in — passes

      A 2x10 never reaches 5 in for code-height steps, which is why a notched 2x10 stringer is the most common undersized-stair mistake. Use 2x12 as the default, LVL or 2x14 for long or heavily loaded stairs, and a solid (uncut) 2x10 or 2x12 with tread brackets if you want a thinner board. Long cut stringers also have a span limit — see the stair span calculator when the run between supports is over 6 ft.

      How many stringers, and how far apart?

      Divide the stair width by the spacing, round up and add one — with at least two stringers on any stair. The spacing comes from the tread material:

      Number of stringers by stair width and spacing
      Stair width18 in on center (1 in+ treads)16 in (5/4 wood decking)12 in (composite / PVC)
      36 in344
      42 in445
      48 in445
      60 in556

      18 in on center is the usual limit for cut stringers under prescriptive deck rules, and the calculator warns above it. Composite and PVC treads often need 12 in — the decking manufacturer’s installation guide sets the spacing for its boards, so check it before you buy lumber.

      First-riser drop, and standard or flush tops

      Every step you walk on is the stringer notch plus a tread. The top of each tread is one tread thickness above its notch — except at the bottom, where you step up from the floor. If the stringer sat on the floor uncut, the first step would be one tread thickness too tall. So you cut the tread thickness off the foot of the stringer.

      If flooring will be laid at the bottom after the stair is built, the floor rises by that much and the bottom step shrinks, so subtract it: drop = tread thickness − bottom flooring. A 1 in tread over a floor that will get ¾ in hardwood needs only a ¼ in drop. If the flooring is thicker than the tread, the drop turns negative — shim the stringer up instead, or lay the stair out from the finished rise using the total rise calculator.

      At the top, a standard stringer stops one riser below the upper floor, which acts as the last step, so there is one notch fewer than risers. A flush top puts a full tread level with the upper floor, adding one notch and one tread of run. The plumb cut at the top bears against the header or a hanger board.

      Cut vs housed stringers

      • Cut (notched) stringers have the step profile sawn into the top edge. They are quick, strong when the throat is deep enough, and standard for basements, decks and carpeted stairs. The calculator checks the throat against the 5 in rule.
      • Housed (routed) stringers stay whole; treads and risers slide into grooves routed in the face and are wedged and glued. They suit finished stairs with exposed side boards. There is no throat, but the board must be deep enough to hold the full step profile with wood above and below it — the calculator asks for the step depth plus 2 in.

      How to read your result

      Result ranges and next steps
      ValueGoodBorderline or failingWhat to do
      Throat5 in or more3½–5 in is below the prescriptive minimum; under 3½ in is too weak to useUse a deeper board, LVL, or a solid stringer with brackets
      Spacing18 in on center or lessOver 18 in for cut stringersAdd a stringer
      LengthCovered by 8–20 ft stockOver 20 ftAdd a landing (the stair calculator splits flights) or use engineered lumber
      First-riser dropZero or positiveNegative: bottom flooring thicker than the treadShim the stringer, or lay out from the finished rise
      Run6 ft or less between supportsOver 6 ft for a cut stringerAdd a mid-span support and check the span

      The riser and tread checks use the code you pick; they matter most in Known riser & tread mode, where you might be copying an old stair that no longer meets code.

      Mistakes that ruin a stringer

      Notching a 2x10For code-height steps a notched 2x10 keeps only about 3¼ in of wood. It may hold at first and then crack along the throat. Start with 2x12.

      Over-cutting the inside cornersRunning the circular saw past the line into the throat weakens every notch. Stop short and finish the corner with a handsaw or jigsaw.

      Forgetting the dropWithout the first-riser drop, the bottom step is one tread thickness taller than the rest — a trip hazard and a code failure, since risers must match within 3/8 in.

      Laying out from the rough riseFlooring at the top or bottom changes the rise. Lay the stringer out from the finished rise, then use the drop for flooring that is not down yet.

      What this calculator does not cover

      • Choosing the layout from available space: use Fit my space in the stair calculator.
      • Structural span and load: long or heavily loaded stringers need a span check — see the stair span calculator.
      • Comfort and steepness: see the stair angle calculator.
      • A full code check of a finished stair: use the stair code checker.
      • Local rules: confirm stringer, spacing and span requirements with your building department; for unusual stairs, have a design professional review the framing.

      Stair stringer FAQs

      What size lumber should I use for stair stringers?

      Use 2x12 for almost every cut stringer. A typical 7¼ in riser with a 10½ in tread notches about 6 in into the board, which leaves 5-5/16 in of throat in a 2x12 (11¼ in actual) but only 3-5/16 in in a 2x10. LVL or a 2x14 adds margin for long or heavily loaded stairs.

      Can I use a 2x10 for stair stringers?

      Not as a cut stringer for a normal stair. Notching a 2x10 for 7-3/16 × 10-1/2 steps leaves about 3-5/16 in of wood, well under the 5 in minimum used by prescriptive deck rules. A 2x10 can work as a solid (uncut) stringer with metal tread brackets or cleats, or for very shallow steps.

      How many stringers do I need for a 36 in stair?

      Three at 18 in on center, which suits interior stairs with 1 in or thicker treads. Decking treads usually need closer spacing: 16 in for 5/4 wood decking gives 4 stringers and 12 in for most composite or PVC boards gives 4 as well on a 36 in stair. The rule is width ÷ spacing, rounded up, plus one.

      How far apart should stair stringers be?

      Cut stringers are commonly limited to 18 in on center under prescriptive deck rules. Thin treads need less: 16 in for 5/4 wood decking and often 12 in for composite or PVC decking — the tread manufacturer’s installation guide sets the number for its product.

      How do I set stair gauges on a framing square?

      Clamp one gauge on the tongue (the short arm) at the riser height and one on the blade (the long arm) at the tread run, both on the outside edge. Lay the square on the board with both gauges touching the top edge, trace the notch, slide along to the end of the tread line and repeat. The calculator gives both settings to the nearest 1/16 in.

      Why do you drop the first riser on a stringer?

      Every tread adds its thickness to the step below it, but the bottom step sits on the floor, which may or may not get flooring. Cutting the tread thickness, minus any flooring still to be laid at the bottom, off the foot of the stringer makes the first step the same height as all the others.

      How long a board do I need for stair stringers?

      Multiply the number of risers by the step diagonal √(riser² + tread²). For 15 risers of 7.20 in on 10½ in treads that is 190.97 in, so buy 16 ft boards. Rises over about 11 ft usually need more than 20 ft of stringer — split the stair with a landing or use engineered lumber.

      What is the difference between a cut and a housed stringer?

      A cut (notched) stringer has the step profile sawn out of its top edge and the treads sit on the notches, so the wood left below the notches — the throat — carries the load. A housed stringer stays whole: the treads and risers fit into routed grooves on its face, so it needs no throat check but a deeper, better-quality board.

      Sources

      1. International Residential Code 2021, Chapter 3, Section R311.7 — Stairways (opens in a new tab)International Code Council. Riser, tread, nosing, width and handrail limits for homes; flight height limit at R311.7.3.
      2. Wisconsin Administrative Code, chapter SPS 325 — deck constructionWisconsin Department of Safety and Professional Services. Prescriptive rules for cut deck stringers: 5 in minimum throat, 18 in maximum spacing and 6 ft maximum horizontal span. Cited by name; read it on the Wisconsin Legislature's administrative code site.
      3. Prescriptive deck construction guidesModel deck-building guides published in the US repeat the same cut-stringer rules (throat, spacing, span). Cited as a group; follow the guide your jurisdiction adopts.
      4. American Softwood Lumber Standard (Voluntary Product Standard PS 20)National Institute of Standards and Technology. Source of dressed lumber sizes: a 2x10 is 9¼ in deep and a 2x12 is 11¼ in.
      5. Decking manufacturers’ installation guidesStringer spacing for composite and PVC treads is product-specific — use the guide for the boards you buy.
      6. International Building Code 2021, Chapter 10, Section 1011 — Stairways (opens in a new tab)International Code Council. Riser, tread and flight limits for commercial buildings.
      7. Approved Document K: Protection from falling, collision and impact (opens in a new tab)UK Government (statutory guidance for England). Maximum riser, maximum pitch and 2R + G range.
      8. National Building Code of Canada 2020 (opens in a new tab)National Research Council Canada. Riser and run limits for stairs.
      9. National Construction Code (opens in a new tab)Australian Building Codes Board. Riser, going and risers-per-flight limits.

      Code text is the final word. Editions and local amendments differ — check the edition your building department enforces.

      Stair layout calculatorsAll 6 tools for planning a straight stair — layout, stringers, total rise, angle, stairwell opening and footprint.View all 6

      Other stair calculator categories