L-Shaped Stair Calculator

Enter your floor-to-floor height and stair size and get a complete L-shaped stair: risers in each flight, where the landing sits and how high, and the two wall lengths the stair takes. Or enter your two walls and let the calculator find the riser count and landing position that fit.

By the Stair-Math TeamUpdated How we check this calculator

What do you know?

Your stair

in

Finished floor to finished floor. Not sure? Work out your total rise.

in

The riser count is rounded to fit your rise exactly.

in

Riser face to riser face, not counting the nosing.

in

Both flights and the landing use this width. 36 in is the IRC minimum.

Landing position
Quick picks:

Turn direction
Top step
Units

Your L-shaped stair

The L-shaped stair in plan, drawn to scale, with both walls dimensioned
Plan view to scale. Leg A and leg B are the wall lengths the stair takes. Drag the corner to change the landing depth; in Fit to two walls, drag the wall ends.

L-stair check

    Solved with your numbers

      Assumptions: a square corner landing at least as deep as the stair is wide; equal risers in both flights; both flights the same width; the nosing counted once, at the bottom of the lower flight. Leg lengths are to the face of the finished stair — wall finishes and stringers are not included.

      Riser limits, landing depth, flight limit and handrail rule from the IRC (R311.7) and the codes listed under Sources; layouts follow from the geometry on this page. Tested against 6 worked cases, including a metric stair, two walls that are too short and a short return wall. See the method · Sources

      How to calculate an L-shaped stair

      An L-shaped stair is a straight stair cut in two, with a square landing at the corner. The riser count comes from the whole rise, exactly as in the stair calculator: total rise ÷ target riser, rounded, then raised or lowered to stay inside your code's riser limits. The landing is the top tread of the lower flight, so it sits one riser height below the next step.

      With n risers of height R, tread depth T, nosing N, stair width W and landing depth Ld:

      lower flight: n1 = ceil(n ÷ 2) risers (or your choice), t1 = n1 − 1 treads, run1 = t1 × T

      upper flight: n2 = n − n1 risers, t2 = n2 − 1 treads (n2 with a flush top tread), run2 = t2 × T

      leg A = run1 + N + Ld · leg B = W + run2

      landing height = n1 × R · stringer = √((flight risers × R)² + run²)

      floor area = W × (run1 + N) + Ld × W + W × run2

      Leg A is the length along the wall the stair starts from, from the bottom nosing to the far side of the landing. Leg B is the length along the return wall, from the outside of the landing to the upper floor edge. Those are the two numbers to mark on the walls.

      Worked examples

      A 9 ft L-stair from the total rise

      1. Inputs108 in rise · 7¼ in target riser · 10½ in treads · 1 in nosing · 36 in wide · 36 in landing · even split · IRC.
      2. Risers108 ÷ 7.25 = 14.9 → 15 risers of 7.20 in (7-3/16").
      3. FlightsLower 8 risers, 7 treads, 7 × 10.5 = 73.50 in run; upper 7 risers, 6 treads, 63.00 in run.
      4. Landing36 × 36 in, its top 8 × 7.2 = 57.60 in (57-5/8") above the lower floor.
      5. WallsLeg A = 73.5 + 1 + 36 = 110.50 in (9' 2-1/2"); leg B = 36 + 63 = 99.00 in (8' 3").
      6. Stringers√(57.6² + 73.5²) = 93.38 in and √(50.4² + 63²) = 80.68 in; floor area 43.38 ft².

      Choose a split of 4 + 11 instead and wall A drops to 68.50 in while wall B grows to 141.00 in; the landing is then 28.80 in up. The floor area is unchanged.

      Fitting the same stair into a 120 × 96 in corner

      1. 15 risers13 treads to place besides the landing. Wall A holds (120 − 1 − 36) ÷ 10.5 → 7 treads, wall B (96 − 36) ÷ 10.5 → 5. Twelve is one short.
      2. 14 risers7.71 in (7-11/16") — still under the 7¾ in IRC maximum — needs 12 treads: 7 on wall A, 5 on wall B. It fits.
      3. ResultLower flight 8 risers, upper 6; leg A 110.50 in (9.50 in spare), leg B 88.50 in (7.50 in spare); landing 61.71 in up. With 15 risers it would need just 1 in more on wall A.

      How much space does an L-shaped stair need?

      Wall lengths for an L-stair with an even split (7¼ in target riser, 10½ in treads, 1 in nosing, square landing, IRC)
      Floor to floorRisers36 in wide: leg A × leg B42 in wide: leg A × leg BLanding height
      7 ft (84 in)12 × 7"7' 5-1/2" × 7' 4-1/2"7' 11-1/2" × 7' 10-1/2"42"
      8 ft (96 in)13 × 7-3/8"8' 4" × 7' 4-1/2"8' 10" × 7' 10-1/2"51-11/16"
      9 ft (108 in)15 × 7-3/16"9' 2-1/2" × 8' 3"9' 8-1/2" × 8' 9"57-5/8"
      10 ft (120 in)17 × 7-1/16"10' 1" × 9' 1-1/2"10' 7" × 9' 7-1/2"63-1/2"
      11 ft (132 in)18 × 7-5/16"10' 1" × 10' 0"10' 7" × 10' 6"66"

      A 42 in stair uses a 42 in landing, so each leg grows by 6 in. Add the wall finish and stringer on the outside of each leg — usually 1½–3 in — and leave clear floor at the bottom and top. To see how the L compares with a straight, U-shaped or spiral stair, use the staircase footprint calculator.

      Landing size and position

      The landing must be at least as deep as the stair is wide, measured in the direction you walk, and under the IRC not less than 36 in (R311.7.6). On an L the landing is square for the minimum: a 36 in stair gets a 36 × 36 in landing. Leave Landing depth blank to use the stair width (36 in minimum for the IRC); enter more if you want room to turn with a sofa or a wardrobe.

      The landing height is the top of the finished landing above the lower finished floor — the number you need to frame the landing platform. Take off the landing's finished floor thickness for the top of the framing.

      Moving the landing is how you dodge a door, a window or a beam. Choose the split and every option is listed in the table under the result, with its landing height and both wall lengths. Two rules limit the choice:

      • Flight limit: neither flight may rise more than 151 in under the IRC or 144 in under the IBC, or have more than 18 risers in Australia — if one does, move the landing.
      • No single steps: a one-riser flight is easy to miss and trip on. Use at least 2 risers in each flight; Australia's NCC requires it.

      Fitting an L-stair between two walls

      When both walls are fixed, choose Fit to two walls and enter the length you can give the stair along each. Wall A is the run from where the stair starts to the corner; wall B runs from the corner to the upper floor edge. The calculator then:

      1. tries every riser count your code allows, closest to your target riser first;
      2. works out how many whole treads fit on each wall after the landing and nosing;
      3. takes the first count whose treads fit, splitting them as evenly as the walls allow.

      If it had to use a different riser count from your target, it says so and tells you how much more wall your target would need. If nothing fits, it gives the shortfall — the extra wall length needed at the fewest risers allowed. The ways out are winders in the corner (about one tread shorter on each wall), a U-shaped stair, or a spiral.

      L-stair with a landing or with winders?

      Corner landing compared with winders, 108 in rise, 36 in stair
      Square landing3 winders
      Wall lengths110½ × 99 in100 × 88½ in
      SafetyA full rest halfway; easiest to useNarrow inside ends; feet must stay near the walkline
      FurnitureEasy to pivot on the landingHard to carry large items round
      CodeLanding depth ≥ stair width, ≥ 36 in (IRC)10 in at the walkline, 6 in minimum at the narrow end (IRC)

      To design the winders themselves, use the winder stair calculator.

      How to read your result

      Result terms and next steps
      TermMeaningNext step
      Leg A / leg BWall length taken by each side of the L, to the face of the stairMark them on the walls; add wall finish and stringer
      Landing heightTop of the finished landing above the lower finished floorFrame the landing to this less its floor finish
      Stringer lengthThe sloped length of each flight, along the pitch lineBuy boards longer than this, then lay out each flight in the stringer calculator
      SpareWall left over in Fit to two wallsUse it for a deeper landing or clear floor at the ends
      Short byExtra combined wall needed at the fewest risers allowedTry winders, a U-turn or a spiral

      Then check headroom over each flight with the stairwell opening calculator, and cut each flight with the stair stringer calculator using its own riser count.

      What this calculator does not cover

      • Straight stairs with a landing part-way along: use the stair calculator.
      • Winders in place of the landing, and 180° turns: use the winder and U-shaped stair calculators.
      • The opening and headroom over the upper flight: use the stairwell opening calculator.
      • Stringer cuts, handrail length and materials — each has its own calculator.

      L-shaped stair FAQs

      How do you calculate an L-shaped staircase?

      Work out the risers for the whole rise first — total rise ÷ about 7¼ in, rounded to a whole number. Split them between two flights; the landing is the top tread of the lower flight. Each flight has one tread fewer than its risers, so the lower flight run is (lower risers − 1) × tread depth. Wall A is that run plus the nosing plus the landing depth; wall B is the stair width plus the upper flight run.

      How big does an L-shaped stair landing need to be?

      At least as deep as the stair is wide, measured in the direction of travel — so a 36 in stair needs at least a 36 × 36 in landing. The IRC also sets 36 in as the minimum depth whatever the width. A deeper landing (42–48 in) makes it easier to turn with furniture.

      Where should the landing go on an L-shaped stair?

      Halfway is the default and gives two flights of about the same length. Move it lower or higher to suit the walls, a door or a window: a lower landing shortens wall A and lengthens wall B, and the floor area stays the same. Keep at least 2 risers in each flight, and keep each flight under the flight limit (151 in of rise under the IRC, 18 risers in Australia).

      How much space does an L-shaped staircase need?

      For a 9 ft rise (108 in) and a 36 in stair with 10½ in treads, an L with a square landing takes about 9 ft 2½ in along one wall and 8 ft 3 in along the other, and covers about 43 ft² of floor. For an 8 ft rise it is about 8 ft 4 in × 7 ft 4½ in.

      Is an L-shaped stair better with a landing or with winders?

      A landing is safer and easier to carry furniture round, and it gives a rest halfway. Winders replace the landing with three wedge-shaped treads, so the stair needs less wall — about 10½ in less on each leg for a 36 in stair — but the treads are narrow at the inside and must meet walkline rules.

      How many steps can you have before a landing?

      Under the IRC one flight may rise at most 151 in (12 ft 7 in) between floors or landings — about 20 risers at 7½ in. The IBC limit is 144 in, and Australia allows at most 18 risers in a flight. Most house stairs are well under the limit; an L-stair splits the rise anyway.

      Does each flight of an L-shaped stair need a handrail?

      Under the IRC, any flight with four or more risers needs a handrail on at least one side, so with an even split both flights usually do. If one flight has fewer than four risers it does not need one by code, but a continuous rail round the landing is safer.

      What is the difference between a quarter-turn and a half-turn stair?

      A quarter-turn stair turns 90° at the landing — an L-shape. A half-turn stair turns 180° and comes back alongside itself — a U-shape or switchback, with a half landing spanning both flights. The U-stair is shorter but twice as wide.

      Sources

      1. International Residential Code 2021, Chapter 3, Section R311.7 — Stairways (opens in a new tab)International Code Council. Width (R311.7.1), headroom (R311.7.2), 151 in flight limit (R311.7.3), walkline (R311.7.4), winders (R311.7.5.2.1), landings at least as deep as the stair is wide and not less than 36 in (R311.7.6), handrails on flights of four or more risers (R311.7.8) and spiral stairs (R311.7.10.1).
      2. International Building Code 2021, Chapter 10, Section 1011 — Stairways (opens in a new tab)International Code Council. Riser and tread limits, 44 in typical minimum width and 144 in flight limit for commercial buildings.
      3. National Construction Code 2019, Volume Two, Part 3.9.1 — Stair construction (opens in a new tab)Australian Building Codes Board. Riser and going limits and 2R + G range (Table 3.9.1.1), no more than 18 and no fewer than 2 risers in each flight.
      4. Approved Document K: Protection from falling, collision and impact (opens in a new tab)UK Government (statutory guidance for England). Maximum riser, maximum pitch and 2R + G range.
      5. National Building Code of Canada 2020 (opens in a new tab)National Research Council Canada. Riser and run limits for stairs.
      6. L-stair geometryDerived from geometry: flight runs, leg lengths, landing height and stringer pitch lengths follow from the riser count, tread depth, nosing, width and landing depth.

      Code text is the final word. Editions and local amendments differ — check the edition your building department enforces.

      Turning & specialty stair calculatorsAll 7 tools for stairs that turn, wind or climb steeply — L-shaped, U-shaped, winder, spiral, curved, ship ladder and attic ladder.View all 7

      Other stair calculator categories