What angle should a ship ladder be?
| Angle | Going | Overlap | Footprint | IRC 5 in going |
|---|---|---|---|---|
| 50° | 7-9/16" | 15/16" | 91-9/16" | Pass |
| 56° | 6-1/16" | 2-7/16" | 75-1/4" | Pass |
| 60° | 5-3/16" | 3-5/16" | 65-11/16" | Pass |
| 63° | 4-9/16" | 3-15/16" | 58-15/16" | Fails |
| 65° | 4-3/16" | 4-5/16" | 54-11/16" | Fails |
| 70° | 3-1/4" | 5-1/4" | 44-9/16" | Fails |
Steeper saves floor but shortens the going — the horizontal distance between nosings, which is where your foot lands. With 9 in risers the IRC 5 in minimum going is reached at 60.9°, which is why many 65–70° kit ladders do not meet the IRC for a loft. The table under your result shows your own ladder at each angle.
IRC and OSHA requirements
| Rule | IRC ship ladder | IRC alternating tread | OSHA ship stair | OSHA alternating tread |
|---|---|---|---|---|
| Angle | — | — | 50–70° | 50–70° |
| Riser | ≤ 9½ in | ≤ 9½ in | 6½–12 in, open | — |
| Going / tread | Going ≥ 5 in; tread + nosing ≥ 8½ in | Going ≥ 5 in; tread + nosing ≥ 8½ in | Tread ≥ 4 in | Tread ≥ 8½ in; open risers if under 9½ in |
| Width | — | Each tread ≥ 7 in | ≥ 18 in | ≥ 7 in at the nosing |
| Handrails | Both sides | Both sides | Both sides | 17–24 in apart |
| Where allowed | Lofts or mezzanines ≤ 200 sq ft, not only a kitchen or bathroom | Where a standard stair is not feasible | ||
In the UK, space-saver (paddle) stairs for loft conversions follow Approved Document K — choose None for the geometry and check the rules there.
How the ship ladder calculator works
With total rise H, target riser Rt, angle α and tread board depth d:
risers n = round(H ÷ Rt), raised if the riser is over 9½ in (IRC) or 12 in (OSHA, None); for an OSHA ship stair lowered if it is under 6½ in · R = H ÷ n · treads = n − 1
going g = R ÷ tan α · overlap = d − g
run = treads × g · footprint = run + d · rail = √(H² + run²)
maximum angle for the IRC going = atan(R ÷ 5 in)
The overlap is how far each tread board reaches back under the one above — what makes a steep ladder feel like a stair underfoot. If it comes out negative the boards do not overlap and the calculator flags it.
Worked examples
A loft ship ladder at 60°
- Inputs108 in rise · 9 in target riser · 60° · 8½ in tread boards · 24 in wide · IRC.
- Risers108 ÷ 9 = 12 risers of 9.00 in; 11 treads.
- Going9 ÷ tan 60° = 5.20 in (5-3/16") — over 5 in; boards overlap 8.5 − 5.20 = 3.30 in.
- SpaceRun 11 × 5.20 = 57.16 in; footprint 65.66 in; rail 122.19 in.
- LimitThe steepest compliant angle is atan(9 ÷ 5) = 60.9°.
The same ladder at 65°
The going drops to 4.20 in and fails the IRC 5 in minimum, even though the footprint shrinks to 54.66 in. The fix is to reduce the angle to 60.9° or less.
An OSHA alternating tread stair at 56°
12 risers of 9 in give a 6.07 in going, 2.93 in overlap and a 75.78 in footprint. With 9 in boards, 8 in treads each side and handrails 22 in apart it meets 1910.25(f); because the boards are under 9½ in deep, the risers must be open.
How much floor space does a ship ladder need?
The footprint runs from the foot of the ladder to the back of the top tread: run + one board depth. Add clear floor at the foot — at least the ladder’s width and about 30 in deep — to step on and off. A 9 ft rise at 60° takes about 65½ in; a conventional stair for the same rise takes 11 ft or more, which is why ship ladders are used for lofts, mezzanines, plant platforms and boats.
Ship ladder vs alternating tread stair
An alternating tread stair (also sold as a paddle stair or space-saver stair) has half-width treads, alternately on the left and right, each riser apart. Each foot gets its own tread, so the going for each foot is twice what it would be on a full-width ladder at the same angle, and you can come down facing forward. The cost is that you must start on the correct foot, and it is no good for carrying things. Choose Alternating tread stair to add the tread-width and handrail-spacing checks.
Using a ship ladder safely
- Descend facing the ladder unless it is an alternating tread stair designed to be walked down forwards.
- Fit handrails on both sides and run them to the upper floor so you have a hold stepping on and off.
- Keep one hand free; pass loads up rather than carrying them.
- Guard the opening at the top, and light the ladder and the landing.
What this calculator does not cover
- Standard stairs under 50°: use the stair calculator and the stair angle calculator.
- Pull-down attic ladders: use the attic ladder calculator.
- Structural design, load ratings, handrail length and cost.
Ship ladder FAQs
What angle should a ship ladder be?
Between 50° and 70° from the floor; OSHA sets that range for ship stairs and alternating tread stairs. For a home loft under the IRC the going must be at least 5 in, so with 9 in risers the steepest compliant angle is about 60.9°. 56–60° is the comfortable range for regular use.
What are standard ship ladder dimensions?
A typical residential ship ladder is about 24 in wide with 9 in risers at around 60°, giving a going of about 5¼ in and tread boards 8½ in deep that overlap by about 3¼ in. For a 9 ft rise it projects about 5½ ft across the floor.
Are ship ladders legal in homes?
Under the IRC, a ship ladder may serve a loft or mezzanine of 200 sq ft or less that does not serve only a kitchen or bathroom, with at least 5 in of tread depth, 8½ in of tread plus nosing, risers up to 9½ in and handrails on both sides. It is not a code stair to bedrooms or an exit route. Check which IRC edition your area adopts, as the section number moves between editions.
What is the difference between a ship ladder and an alternating tread stair?
A ship ladder has full-width treads you climb like a very steep stair. An alternating tread stair has half-width treads offset left and right, so each foot lands on its own tread — it lets you descend facing forward in less space, but you must start on the correct foot.
Ship ladder vs stairs vs ladder — where is the line?
Under about 50° it is a stair and should be designed as one. Between 50° and 70° it is a ship ladder or alternating tread stair. Above 70° the treads stack almost vertically and it is a ladder — used facing in, with rungs rather than treads.
How much floor space does a ship ladder need?
The footprint is the run plus one tread board. For a 9 ft rise at 60° with 9 in risers and 8½ in boards that is about 65½ in; at 65° about 54½ in, but the going drops under 5 in. Leave clear floor at the foot to step off.
What are the OSHA requirements for ship stairs?
Under 29 CFR 1910.25(e): a slope of 50–70°, open risers of 6½–12 in, treads at least 4 in deep and at least 18 in wide, and handrails on both sides. OSHA allows ship stairs only where a standard stair is not feasible.
How do you use a ship ladder safely?
Always come down facing the ladder, hold both handrails, and keep one hand free — carry loads up in a bag or pass them up. Keep the handrails continuous to the upper floor so you have something to hold as you step on and off.
Sources
- OSHA 29 CFR 1910.25 — Stairways (opens in a new tab)US Department of Labor. Standard stairs 30–50° with risers up to 9½ in and treads at least 9½ in (c); ship stairs 50–70°, open risers 6½–12 in, treads at least 4 in deep and 18 in wide (e); alternating tread-type stairs 50–70°, handrails 17–24 in apart, treads at least 8½ in deep, open risers when under 9½ in, at least 7 in wide at the nosing (f).
- International Residential Code — ship ladders and alternating tread devices (opens in a new tab)International Code Council. Ship ladders (R311.7.12 in the 2018 and 2021 editions) and alternating tread devices (R311.7.11): tread depth at least 5 in, tread plus nosing at least 8½ in, risers up to 9½ in, handrails both sides, alternating treads at least 7 in wide; permitted to lofts or mezzanines of 200 sq ft or less not serving only a kitchen or bathroom. Section numbers vary by edition.
- International Building Code 2021, Section 1011 — ship ladder and alternating tread exceptions (opens in a new tab)International Code Council. Ship ladders and alternating tread devices permitted only in the limited non-egress locations the IBC lists.
- Ship ladder geometryDerived from geometry: going = riser ÷ tan(angle), run = treads × going, rail length = √(rise² + run²).
Code text is the final word. Editions and local amendments differ — check the edition your building department enforces.
Related calculators
- Attic ladder calculatorA pull-down alternative
- Stair angle calculatorIs it a stair, ship ladder or ladder?
- Spiral staircase calculatorA compact stair you can walk down
- Staircase footprint calculatorCompare the space with other layouts
- Stair calculatorLay out a full stair instead
Other stair calculator categories